{"product_id":"mydata-mycronic-safety-switch-e-011-0011","title":"Mycronic Safety Switch E-011-0011","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis is a safety switch plate assembly used in MyData\/Mycronic MY-series pick-and-place machines, providing the mounting plate and actuator element for a safety interlock switch associated with machine guard covers, access panels, or safety doors.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eKey characteristics:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eApplication: MyData\/Mycronic MY-series pick-and-place machines\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFunction: Serves as the actuator plate component of a safety interlock switch assembly, providing:\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePhysical actuator element that engages the safety switch mechanism when the associated guard cover or access panel is closed\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePrecise actuation geometry ensuring reliable and repeatable safety switch engagement and disengagement with guard position changes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eMounting plate providing secure attachment of the actuator element to the moving guard or cover\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWorking in conjunction with the corresponding safety switch body to complete the safety interlock circuit when the guard is correctly closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eManufacturer: MyData\/Mycronic (E-prefix indicates an electrical or component-level part number)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePart number: E-011-0011\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eType: Safety switch actuator plate \/ safety interlock switch plate assembly\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCategory: Machine safety system component\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCriticality: Extremely high — as a safety interlock component, correct function is essential for operator safety and regulatory compliance; any suspected fault or damage must be addressed immediately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSafety Switch System Components:\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003ePart Number\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eComponent\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eE-011-0011\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSafety Switch Plate\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eActuator plate engaging safety switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eE-011-0026\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSafety Button\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eOperator safety control input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eL-024-0182\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eSafety Switch Y Hood\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eY hood safety interlock switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eImportant Notes on Replacement:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eReplacement must be performed by qualified personnel\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFull safety interlock functional verification mandatory after replacement\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eActuator plate alignment must be verified to ensure correct switch engagement geometry\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eEngage Mycronic service support for installation and safety validation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mycronic \/MyData","offers":[{"title":"Default Title","offer_id":45533901160492,"sku":"E-011-0011","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/7672\/5292\/files\/Mycronic_Safety_switch_E-011-0011.jpg?v=1778703122","url":"https:\/\/lewis-clark.com\/products\/mydata-mycronic-safety-switch-e-011-0011","provider":"Lewis \u0026 Clark LLC","version":"1.0","type":"link"}