{"product_id":"juki-optical-fiber-sensor-hpf-t048-with-nozzle-sensor-40045484-cds","title":"JUKI Optical Fiber Sensor HPF-T048 with Nozzle Sensor 40045484\/CDS","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis is a combined optical fiber sensor and nozzle sensor assembly used in JUKI SMT pick-and-place machines, providing non-contact optical detection for nozzle presence, component pickup verification, and placement head sensing functions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eKey characteristics:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eApplication: JUKI SMT pick-and-place machines (specific model compatibility dependent on machine series)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFunction: Provides optical fiber-based non-contact sensing for critical placement head functions including:\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eNozzle presence detection — verifying correct nozzle seating and presence on placement head spindle\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eComponent pickup verification — confirming successful component pickup by detecting component presence at nozzle tip\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eComponent release confirmation — verifying clean component release after placement\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eNozzle condition monitoring — detecting missing, broken, or incorrectly seated nozzles before placement operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eManufacturer: JUKI Corporation \/ HPF-T048 optical fiber sensor by OEM sensor supplier\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePart number: 40045484\/CDS (JUKI internal part number); HPF-T048 (OEM sensor model designation)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eType: Optical fiber sensor with integrated nozzle detection assembly\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eSensing Principle: Optical fiber — transmits and receives light via fiber optic cable for non-contact, high-speed detection in the confined space of the placement head\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCategory: Machine sensor \/ placement head component\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWear Item: Optical fiber sensors are subject to fiber damage, contamination, and optical degradation over time; regular inspection recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSigns of Sensor Degradation:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFalse component pickup or release errors\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eNozzle presence detection failures\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIncreased placement errors or head fault codes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIntermittent sensor signal in machine software\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Juki","offers":[{"title":"Default Title","offer_id":45518471299116,"sku":"40045484\/CDS","price":2350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/7672\/5292\/files\/JUKI_Optical_Fiber_Sensor_HPF-T048_with_Nozzle_Sensor_40045484_CDS.jpg?v=1779116041","url":"https:\/\/lewis-clark.com\/products\/juki-optical-fiber-sensor-hpf-t048-with-nozzle-sensor-40045484-cds","provider":"Lewis \u0026 Clark LLC","version":"1.0","type":"link"}