{"product_id":"mycronic-fi-motor-with-encoder-l-029-0204c","title":"Mycronic Fi Motor with Encoder L-029-0204C","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis is a Fi-axis servo motor with integrated encoder assembly used in MyData\/Mycronic MY-series pick-and-place machines, providing the complete drive motor and position feedback unit for the Fi-axis (phi\/rotation axis) belt drive system within the placement head assembly.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eKey characteristics:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eApplication: MyData\/Mycronic MY-series pick-and-place machines equipped with Fi-axis belt drive placement head\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFunction: Provides the complete Fi-axis drive and position feedback system combining two interdependent components:\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFi-axis Servo Motor — drives the Fi-axis belt transmission system controlling nozzle rotation or placement head rotational positioning with high speed and precise angular control\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIntegrated Encoder — provides real-time angular position feedback to the machine's motion control system for closed-loop Fi-axis positioning accuracy and velocity control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eManufacturer: MyData\/Mycronic (L-prefix indicates a Mycronic assembly-level part number)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePart number: L-029-0204C (\"C\" suffix denotes a specific revision level)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eType: Fi-axis servo motor with integrated encoder assembly\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCategory: Machine motion \/ placement head drive component\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCriticality: High — failure results in loss of Fi-axis rotational control causing placement angle errors or placement head downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eFi-Axis Drive Component Summary:\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003ePart Number\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eComponent\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eL-029-0204C\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFi Motor with Encoder\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFi-axis drive motor and position feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eD-012-0718-3\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBelt Pulley Fi-Motor\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFi-axis motor belt drive pulley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eL-029-0193\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eXFMB Fi Motor Board Cable\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFi-axis motor board cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eK-022-0007\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eBelt T2.5\/177.5 B=5\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"\u003eFi-axis miniature timing belt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSigns of Fi Motor Degradation:\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFi-axis positioning errors or rotation inaccuracy\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eEncoder feedback faults or error codes in machine software\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eAbnormal motor noise during Fi-axis operation\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBelt drive irregularities caused by motor torque inconsistency\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFi-axis following errors during high-speed operation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mycronic \/MyData","offers":[{"title":"Default Title","offer_id":45536005783596,"sku":"L-029-0204C","price":573.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/7672\/5292\/files\/Mycronic_Fi_Motor_with_Encoder_L-029-0204C.jpg?v=1778687909","url":"https:\/\/lewis-clark.com\/en-ca\/products\/mycronic-fi-motor-with-encoder-l-029-0204c","provider":"Lewis \u0026 Clark LLC","version":"1.0","type":"link"}